The setting of hot water temperature
'+/- function (iC Range only)
(ancillary function: Scroll and +/- function)
The setting of boiler temperature
(max flow temperature) +/- function
(ancillary function: OK and escape)
Eco-function DHW on/off. (iC Range only)
Press for 6 seconds for boiler information
Reset Button
Commissioning function (Do not use. For service purposes only)
Pump function (Press both – buttons for 6 seconds) (iC & iS-Range only)
Visible when the DHW program is active
Flashing when there is a heat demand for DHW (iC Range only)
Visible when the heating program is active
Flashing when there is a heat demain for heating
Visible when the boiler is active for heating or DHW
Visible when the DHW comfort function is not active
Error indication (accompanied by a code)
Service-mode or blocking
Visible when the pump is set to continuously
Flashing when the frost program is active (iC & iS Range only)
Error Codes:
Blocking Code with a Spanner symbol
Error is temporary and will clear itself or will lock the boiler after several attempts (error)
Error Code with bell symbol
The boiler is locked and can only be remedied by a reset and/or intervention by a service technician
10 | Outside sensor error |
20 | Flow sensor error |
40 | Return sensor error |
50 | DHW sensor error (iC-Range only) |
61 | Bus communication error |
78 | Water pressure out of range |
105 |
Venting program is active when power is turned on or interrupted (runs approx. 7 mins)
|
110 | Safety temperature exceeded |